  1.                          SECTION 05311
  2.  
  3.                  NON-COMPOSITE STEEL FORM DECK
  4. NOTE ** This section is based on a short form specification
  5.         of the Steel Deck Institute and products
  6.         manufactured by United Steel Deck, Inc., which is
  7.         headquartered at the following address:
  8. NOTE **      475 Springfield Avenue
  9. NOTE **      Summit, NJ  07902-0662
  10. NOTE **      Telephone:  908-277-1617 in New Jersey, or 800-
  11.         631-1215.
  12. NOTE **      Fax:        908-277-1619.
  13. NOTE **
  14. NOTE ** Non-composite form deck for both structural
  15.         concrete and non-structural lightweight insulating
  16.         fills, in depths from 9/16 inch to 2 inches and in
  17.         gages from 18 to 28, are available to accommodate a
  18.         wide variety of span and load conditions.
  19. NOTE **
  20. NOTE ** United Steel Deck, Inc. is a member of the Steel
  21.         Deck Institute, and the products furnished by
  22.         United Steel Deck, Inc. conform to the
  23.         specifications of the Steel Deck Institute.
  24. NOTE **
  25. NOTE ** SECTION 05311 - NON-COMPOSITE STEEL FORM DECK,
  26.         Copyright 1996, The Architect's Catalog, Inc.
  27.  
  28.  
  29. PART 1  GENERAL
  30.  
  31. 1.1 SECTION INCLUDES
  32.  
  33.     A.  Non-composite steel form deck.
  34.  
  35.     B.  Closures and fillers.
  36.  
  37.     C.  Fastening of deck.
  38.  
  39. 1.2 RELATED SECTIONS
  40. NOTE ** Delete any sections below not relevant to this
  41.         project;  add others as required.
  42.  
  43.     A.  Section 03300 - Cast-In-Place Concrete.
  44.  
  45.     B.  Section 05120 - Structural Steel.
  46.  
  47.     C.  Section 07220 - Roof and Deck Insulation.
  48.  
  49. 1.3 REFERENCES
  50. NOTE ** Delete references from the list below that are not
  51.         actually required by the text of the edited
  52.         section.
  53.  
  54.     A.  ASTM A 611 - Standard Specification for Steel, Sheet,
  55.         Carbon, Cold-Rolled, Structural Quality.
  56.  
  57.     B.  ASTM A 653/A 653M - Steel Sheet, Zinc-Coated (Galvanized)
  58.         or Zinc-Iron Alloy Coated (Galvannealed) by the Hot-Dip
  59.         Process.
  60.  
  61.     C.  ASTM A 924 - Standard Specification for General
  62.         Requirements for Steel Sheet, Metallic-Coated by the Hot-
  63.         Dip Process.
  64.  
  65.     D.  AWS D1.3 - Structural Welding Code - Sheet Steel;
  66.         American Welding Society.
  67.  
  68.     E.  Fire Resistance Directory; Underwriters Laboratories Inc.
  69.         (UL).
  70.  
  71.     F.  SDI 29 - Steel Deck Institute Design Manual for Composite
  72.         Decks, Form Decks, Roof Decks, and Cellular Metal Floor
  73.         Deck with Electrical Distribution; Steel Deck Institute,
  74.         Inc. (SDI).
  75.  
  76.     G.  SDI DDM02 - Diaphragm Design Manual; Steel Deck
  77.         Institute, Inc. (SDI).
  78.  
  79.     H.  Specification for the Design of Cold-Formed Steel
  80.         Structural Members; American Iron and Steel Institute
  81.         (AISI).
  82.  
  83. 1.4 SUBMITTALS
  84.  
  85.     A.  Submit under provisions of Section 01300.
  86.  
  87.     B.  Product Data:
  88.         1.  Submit for each type of decking specified, including
  89.             dimensions of individual components, profiles, and
  90.             finishes.
  91.         2.  Mechanical fasteners:  Test reports from a qualified
  92.             independent testing agency evidencing compliance with
  93.             requirements based on comprehensive testing.
  94.  
  95.     C.  Shop Drawings:  Show location of deck units, anchorage
  96.         details, and other information required for a thorough
  97.         review.
  98.  
  99.     D.  Product Certificates:  Signed by the manufacturer of the
  100.         steel deck, certifying the supplied products comply with
  101.         specified requirements.
  102.  
  103.     E.  Welder Certificates.
  104.  
  105. 1.5 QUALITY ASSURANCE
  106.  
  107.     A.  Manufacturer Qualifications:  Member of the Steel Deck
  108.         Institute.
  109.  
  110.     B.  Codes and Standards:  Comply with applicable provisions
  111.         of the following specifications:
  112.         1.  American Iron and Steel Institute (AISI).
  113.         2.  American Welding Society (ANSI/AWS D1.3 Structural
  114.             Welding Code/Sheet Steel).
  115.         3.  Steel Deck Institute (SDI).
  116.  
  117.     C.  Each welder shall have satisfactorily passed A.W.S.
  118.         Qualification tests for welding processes involved, and
  119.         if applicable, shall have undergone recertification.
  120.  
  121. 1.6 DELIVERY, STORAGE, AND HANDLING
  122.  
  123.     A.  Protect steel deck from corrosion, deformation, and other
  124.         damage during delivery, storage and handling.
  125.  
  126.     B.  If ground storage is needed, store deck bundles off the
  127.         ground, with one end elevated to provide drainage.
  128.         Protect bundles against condensation with a ventilated
  129.         waterproof covering.  Stack bundles so there is no danger
  130.         of tipping, sliding, rolling, shifting or material
  131.         damage.  Check bundles periodically for tightness, and
  132.         retighten as necessary so wind cannot loosen sheets.
  133.  
  134.     C.  Place deck bundles on the building frame near a main
  135.         supporting beam at a column or wall.  Do not place
  136.         bundles on unbolted frames or on unattached or unbridged
  137.         joists.  Ensure that the structural frame is properly
  138.         braced to receive the bundles.
  139.  
  140.  
  141. PART 2  PRODUCTS
  142.  
  143. 2.1 MANUFACTURER
  144.  
  145.     A.  Provide products fabricated by United Steel Deck, Inc.;
  146.         14 Harmich Rd. South Plainfield, NJ  07080.  Telephone:
  147.         908-277-1617 or 800-631-1215; Fax: 908-277-1619.
  148.  
  149. 2.2 MATERIALS
  150. NOTE ** Delete 1 of the 2 following paragraphs.
  151.  
  152.     A.  Sheet Steel for Galvanized Deck and Accessories:  ASTM A
  153.         653 Structural Quality, minimum yield strength of 33 ksi
  154.         (230 MPa).  Galvanizing:  ASTM A 924 with a minimum
  155.         coating class of G30 as defined in ASTM A 653.
  156.  
  157.     B.  Sheet Steel for Deck and Accessories:  ASTM A 611 with a
  158.         minimum yield strength of 33 ksi (230 Mpa).
  159. NOTE ** Delete 2 of the 3 following paragraphs.
  160.  
  161.     C.  Deck Type and Thickness:  As shown on the drawings.
  162.  
  163.     D.  Deck shall be ______ with a minimum metal thickness of
  164.         _____.
  165.  
  166.     E.  Select deck to provide the load capacities shown on the
  167.         drawings and as determined using the Steel Deck Institute
  168.         construction loading criteria.
  169.  
  170.     F.  Whenever possible, deck shall be multi-span and shall not
  171.         require shoring during the concrete placement procedure.
  172. NOTE ** Delete the following paragraph if no fire-resistant
  173.         units are required.  If retained, insert the UL
  174.         Design Number in the specification or on the
  175.         drawings.
  176.  
  177.     G.  Where fire resistance rated assemblies are required,
  178.         provide UL-listed units.  Identify steel deck bundles
  179.         with labels bearing the UL mark.
  180.         1.  UL Design Number:  ______.
  181.         2.  UL Design Number:  As indicated on the drawings.
  182.  
  183. 2.3 ACCESSORIES
  184.  
  185.     A.  Pour stops, column closures, end closures, cover plates,
  186.         and girder fillers shall be the type required by the
  187.         Steel Deck Institute.
  188.  
  189.     B.  Mechanical fasteners or welds are acceptable for
  190.         accessory attachments.
  191.  
  192.  
  193. PART 3  EXECUTION
  194.  
  195. 3.1 EXAMINATION
  196.  
  197.     A.  Examine support framing and field conditions for
  198.         compliance with requirements for installation tolerances
  199.         and other conditions affecting performance of work of
  200.         this section.
  201.  
  202. 3.2 PREPARATION
  203.  
  204.     A.  Place deck in accordance with approved placement plans.
  205.  
  206.     B.  Do not place deck panels on concrete support structure
  207.         until concrete has cured and is dry.
  208.  
  209.     C.  Locate deck bundles to prevent overloading of support
  210.         members.
  211.  
  212. 3.3 INSTALLATION, GENERAL
  213.  
  214.     A.  Install deck panels and accessories according to Steel
  215.         Deck Institute specifications and recommendations, and in
  216.         accordance with placement plans and requirements of this
  217.         section.
  218.  
  219.     B.  Install temporary shoring, if required, before placing
  220.         deck panels.
  221.  
  222.     C.  Place deck panels on structural supports and adjust to
  223.         final position with ends aligned.  Attach firmly to the
  224.         supports immediately after placement in order to form a
  225.         safe working platform.
  226.  
  227.     D.  Cut and neatly fit deck units and accessories around
  228.         openings and other work projecting through or adjacent to
  229.         the decking.
  230.  
  231.     E.  Do not cut unscheduled openings through the deck without
  232.         the approval of the Architect; reinforce openings as
  233.         directed.
  234.  
  235. 3.4 INSTALLATION, FORM DECK
  236.  
  237.     A.  Anchor deck units to steel supporting members by arc spot
  238.         puddle welds of the following diameter and spacing, or
  239.         fillet welds of equal strength:
  240.         1.  For deck units with metal thickness equal to or
  241.             greater than 0.028 inches (22 gage, 0.7 mm) use 5/8
  242.             inch (15 mm) minimum visible diameter welds with the
  243.             weld pattern shown on the design drawings.
  244.         2.  For deck units with metal thickness less than 0.028
  245.             inches (22 gage, 0.7 mm) weld deck through
  246.             manufacturer's standard welding washers with the weld
  247.             pattern shown on the Drawings.
  248.         3.  Mechanical fasteners, either powder actuated or
  249.             pneumatically driven, or screws may be used in lieu
  250.             of welding to fasten deck to supporting framing,
  251.             provided they have been specifically approved by the
  252.             Architect.
  253.         4.  Fasten side laps and perimeter edges of units between
  254.             supports at intervals not exceeding 36 inches (1 m)
  255.             on center, using one of the following methods:
  256.             a.  #10 self drilling screws;
  257.             b.  Crimp or button punch;
  258.             c.  Arc puddle welds - 5/8 inch (15 mm) minimum
  259.                 visible diameter or 1 inch (25 mm) long fillet
  260.                 welds.
  261.  
  262.     B.  Install deck ends over supports with a minimum end
  263.         bearing of 1.5 inches (40 mm).
  264.  
  265.     C.  Fasten pour stops and girder fillers to supporting
  266.         structure according to manufacturer's recommendations.
  267.  
  268.     D.  Fasten column closures, cell closures, and Z closures to
  269.         deck to provide tight fitting closures at open ends of
  270.         ribs and sides of decking.  Fasten cell closures at
  271.         changes of direction of deck units unless otherwise
  272.         directed.
  273.  
  274. 3.5 REPAIRS
  275.  
  276.     A.  Before concrete placement, inspect deck for tears, dents,
  277.         or other damage that may prevent the deck from acting as
  278.         a tight and substantial form.  Determine the need for the
  279.         repair or temporary shoring of deck.
  280.  